Pressure regulators and valvesFR Régulateurs de pression et vannes (réducteur de pression, vanne de secteur, ventouse, clapet anti-retour)TR Basınç regülatörleri ve vanalar (basınç düşürücü, hidrolik vana, vantuz, çek valf)
Also called: pressure reducer, zone valve, air vent, backflow preventer
0.8–2.8 barEstablished practice
Regulators and valves keep each part of the network at the right pressure and protect it. Emitters only give their rated flow at the pressure they were designed for.
- How it works
- A regulator at the start of each zone reduces pressure to the emitter rating, allowing for losses downstream. Zone valves (manual or automatic) switch blocks on and off; air and vacuum relief valves at high points stop soil being sucked into emitters; a backflow preventer keeps fertilizer out of the water source.
- Range and accuracy
- Drip tape is typically run at about 12–15 psi (0.8–1.0 bar); PC drippers at 15–40 psi (1.0–2.8 bar). Gauges before and after filters and at the end of the lines show leaks, clogging or poor regulation.
- Limits
- Poor pressure regulation is a common cause of low emitter flow. Regulators and valves must be maintained, and air valves cannot stop backpressure, only back-siphoning.