Salinity of irrigation water (ECw) and leaching requirementFR Salinité de l’eau d’irrigation (CEw) et besoin de lessivage (eau salée, salinisation, lessivage)TR Sulama suyu tuzluluğu (ECw) ve yıkama gereksinimi (tuzlu su, tuzlanma, tuz yıkama)
Also called: salty water, salt build-up, leaching
Established practice
All irrigation water carries dissolved salts; as plants take up water, salts stay behind and build up in the root zone. Measuring the water’s electrical conductivity (ECw) tells you how much salt it brings and how much extra water is needed to wash it down.
- How it works
- Salts lower the osmotic potential of soil water, so roots must work harder to extract water; the effect adds to soil drying and looks like drought. Applying a little more water than the crop uses (the leaching fraction) carries salts below the roots. The leaching requirement is estimated as LR = ECw / (5 × ECe − ECw), where ECe is the soil salinity the crop tolerates.
- Range and accuracy
- FAO-29 guideline: no restriction below ECw 0.7 dS/m (TDS < 450 mg/l), slight to moderate 0.7–3.0 dS/m, severe above 3.0 dS/m (TDS > 2000 mg/l). Example: maize with ECw 1.2 dS/m needs LR ≈ 0.10 for 90% yield and ≈ 0.16 for full yield. At a 15–20% leaching fraction, soil ECe ≈ 1.5 × ECw.
- Limits
- Leaching only works if the soil drains; with a high water table, extra water can raise salinity instead. The guideline values assume average conditions and must be adapted to crop tolerance, climate and soil.
Linked fromSoil › Saline and sodic soils, Soil › Alluvial soils of the river plains, Soil › Salinization of irrigated land
Sources: [24]