Air temperature and humidity sensorFR Capteur de température et d'humidité de l'air (Thermo-hygromètre)TR Hava sıcaklığı ve nem sensörü (Termohigrometre)

Also called: Temp/RH probe

Air temperature and relative humidity: the inputs for frost warnings, disease models, vapor pressure deficit (VPD) and evapotranspiration.

How it works
Temperature comes from a thermistor or platinum resistance element; humidity from a thin polymer film whose capacitance changes as it absorbs water vapor. Both sit inside a ventilated radiation shield so the sun does not heat them.
Range and accuracy
About −40 to +60 °C (±0.2–0.5 °C) and 0–100% relative humidity (about ±2–3%, worse above about 90%). Usually measured at about 1.5–2 m.
Limits
Without a proper shield, readings can be a few degrees too high on sunny, calm days. Humidity sensors drift and become less accurate near saturation.

Sources: [85] [84]

Sources

  1. Your Farm Weather Station: Installation and Maintenance Guidelines (AE502). University of Florida IFAS Extension.
  2. Crop evapotranspiration: Guidelines for computing crop water requirements (FAO Irrigation and Drainage Paper 56). Allen, R.G., Pereira, L.S., Raes, D. and Smith, M., FAO, 1998.