How soil is measured, grouped by what is measured: water, salinity, pH, nutrients, organic matter, temperature and compaction. Each method shows where it works (lab, in the soil, handheld, on a moving machine or from above), whether it measures directly or through a proxy, and its typical range, accuracy and limits.
Reliability: High = a reference method, or validated against one with small errors. Medium = works well with a site- or soil-specific calibration; errors vary. Low = semi-quantitative, large errors, or not yet proven in the field. Not reliable = does not measure what it claims. Based on the cited sources.
How deep does each method read?
Bars show the depth each method measures or is usually installed at, from shallow (left) to deep (right). Lab methods use samples taken at the chosen depth and are not shown.
No method in this selection has a fixed measuring depth (lab methods use samples taken at any depth).
What is measured, and where
Number of methods in this atlas for each soil property (rows) and each way of measuring (columns). Darker = more methods. Click a row to jump to its group.
Also called: Oven-dry method, thermogravimetric method
Gravimetric, chemical analysisReliability: HighLabDirectSpot reading€Reference method
The water content of a soil sample, measured directly by weighing. It is the reference method that every soil moisture sensor is calibrated and checked against.
How it works
A soil sample is weighed, dried in an oven at 105 °C until its mass stops changing (usually 24 h or more), and weighed again; the mass lost is the water. Dividing by the dry mass gives the gravimetric water content (g/g); multiplying by the bulk density (dry mass per unit volume of soil), or sampling a known volume with a core, gives the volumetric water content (m³/m³).
Range and accuracy
Any water content from oven-dry to saturation. With good practice, better than 0.001 g/g on a mass basis and better than 0.01 m³/m³ (1%) on a volume basis.
Limits
Slow, labor-intensive and destructive: the same spot can never be measured twice, so it cannot follow changes over time. Using an average bulk density instead of the sample's own volume often adds error, and soils rich in organic matter can lose mass that is not water.
Dielectric, time domainReliability: HighIn situHandheldProxy, needs calibrationContinuous€€€Commercial
Volumetric water content, and often the bulk electrical conductivity of the soil. Often regarded as the most accurate electromagnetic method and used as a benchmark for other moisture sensors.
How it works
Time domain reflectometry: an electromagnetic pulse runs along metal rods pushed into the soil and reflects at their ends. The travel time grows with the soil's dielectric permittivity, which depends mainly on water; an empirical equation (Topp) converts it to water content.
Range and accuracy
About 0–50% volumetric water content, typically about ±2% (0.02 m³/m³) with proper calibration. Rods are usually 10–30 cm long and can also be buried horizontally at depth.
Limits
More expensive than capacitance sensors. In very saline or clay-rich soils the pulse fades and readings fail. The rods need good contact with the soil.
Volumetric water content of the soil around the probe — how much of the soil volume is water. One of the most widely used sensors for irrigation scheduling, sold as single-point sensors buried at one depth or as profile probes that read several depths inside one access tube.
How it works
Two electrodes and the soil between them form a capacitor. Water has a far higher dielectric permittivity (about 80) than soil minerals (about 4) or air (1), so more water means higher capacitance, read as a change in oscillator frequency and converted to water content with a calibration curve.
Range and accuracy
Percent volumetric water content, roughly 0–50%. At best about ±2–3% with a field calibration for the specific soil; errors can be much larger in clay-rich or saline soils, and factory calibrations are often inaccurate. Profile probes read several depths, e.g. every 10 cm down to about 1 m.
Limits
Measures only a small volume next to the probe, so air gaps from poor installation give false readings. Salinity and temperature shift the signal.
Dielectric, time domainReliability: HighIn situProxy, needs calibrationContinuous€€Commercial
Volumetric water content, like TDR, from the speed of an electrical pulse in the soil. A lower-cost design that keeps TDR-like accuracy for logging soil moisture in the root zone.
How it works
Transmission instead of reflection: the pulse travels once along a loop of rods buried in the soil and is picked up at the far end, so the sensor times a one-way trip instead of TDR's round trip. The travel time gives the dielectric permittivity, which is converted to water content with the same equations as TDR (e.g. Topp). The electronics sit in the probe head, avoiding signal loss in long cables.
Range and accuracy
Percent volumetric water content over the full moisture range. In a laboratory comparison it agreed with two TDR instruments within about 3 permittivity units across permittivities of 9 to 80 (from dry-ish soil to pure water).
Limits
The rod loop usually has to be buried in a dug trench rather than pushed in, which can change the soil density around it. Long rods weaken the high-frequency part of the pulse, and like all dielectric sensors it is affected by salinity.
Volumetric water content down the soil profile, read at several depths through a permanent access tube. When calibrated in the field, it is still regarded as the most accurate and precise field method for profile water content and soil water balance studies.
How it works
A small radioactive source (americium-241 with beryllium) lowered into the tube emits fast neutrons. They slow down mainly by colliding with hydrogen atoms, which in soil are mostly in water, and a detector counts the slow neutrons that come back: more water, more slow neutrons. The count is converted to water content with a field calibration.
Range and accuracy
Percent volumetric water content over the full range. With a good field calibration, errors below 0.01 m³/m³ (1%) are possible, even at 10 cm depth using a depth-control stand. Each reading averages a sphere roughly 20–30 cm in radius, larger in drier soil.
Limits
The radioactive source requires licensing, safety training, monitoring and strict transport rules. Readings are taken by hand, so it does not log continuously, it is less reliable near the surface (top 30 cm), and manufacturer calibrations are seldom useful.
The average soil water content over a whole field, measured without touching the soil. It fills the gap between point sensors (a few liters of soil) and satellites (kilometers).
How it works
Cosmic rays create fast neutrons in the air and soil. Hydrogen, mostly in soil water, slows these neutrons down, so a detector standing above the ground counts fewer fast neutrons when the soil is wetter. Because neutrons mix in the air over hundreds of meters, one detector sees a large area; mounted on a vehicle (a “rover”) it can map soil moisture along roads.
Range and accuracy
Volumetric water content averaged over a footprint of about 130–240 m radius (roughly 5–18 ha) and a depth of about 15–83 cm, shallower when the soil is wet. Counts are usually summed over about 1 hour.
Limits
Counts must be corrected for air pressure, air humidity and changes in incoming cosmic rays, and calibrated with many soil samples in the footprint. Other hydrogen in the footprint, such as water bound in clay minerals, snow or vegetation, also affects the signal, and the sensing depth changes with wetness.
Surface soil moisture mapped from space over whole regions every few days. Useful for drought monitoring and regional water balance, not for deciding when to irrigate one field.
How it works
Wet soil has a much higher dielectric permittivity than dry soil, which changes how it emits and reflects microwaves. Passive radiometers (SMAP, SMOS) measure the natural L-band microwave emission (about 1.4 GHz); radars such as Sentinel-1 send C-band pulses and measure the backscatter. Models convert the signal to water content, correcting for vegetation and surface roughness.
Range and accuracy
Volumetric water content of roughly the top 5 cm. SMAP's radiometer sees about 40 km footprints (gridded at 36 km and 9 km) with a target accuracy of 0.04 m³/m³ (4%); combined SMAP and Sentinel-1 products at 3 km and 1 km reach errors of about 0.05 m³/m³. Revisit every 2–3 days.
Limits
Sees only the top few centimeters, not the root zone, and one pixel mixes many fields. Dense vegetation, rough or frozen ground and snow degrade the retrieval.
Soil water tension (matric potential): how strongly the soil holds its water, which is what roots actually feel. Tells you when to irrigate rather than how much water is there.
How it works
A sealed, water-filled tube ends in a porous ceramic cup buried in the root zone. As the soil dries it pulls water out through the ceramic, creating a vacuum inside the tube that a gauge or pressure transducer reads.
Range and accuracy
0 to about −80 kPa (centibars). Wet soil reads near 0; values around −20 to −60 kPa are common irrigation triggers, depending on crop and soil.
Limits
Stops working in drier soil when air enters through the ceramic. Needs refilling and maintenance, and can be damaged by frost.
Soil water tension, like a tensiometer, but with no water to refill and a wider range into drier soil. Cheap enough to install at several depths and spots.
How it works
Two electrodes sit inside a porous granular block that wets and dries in balance with the surrounding soil. The electrical resistance between them rises as the block dries and is converted to kPa, with a correction for soil temperature.
Range and accuracy
About 0 to −200 kPa. Less precise in very wet soil (0 to −10 kPa).
Limits
Responds slowly to fast wetting and drying, and individual sensors vary. Readings depend on good soil contact and can still be affected by high salinity.
Soil water tension in moderately dry soil. The older, simpler ancestor of the granular matrix sensor: very cheap, but it works over a narrower and drier range and slowly dissolves.
How it works
Two electrodes are cast in a block made of gypsum (calcium sulfate). The block wets and dries with the soil; dissolved gypsum makes its water conductive, so the electrical resistance rises as the block dries and is converted to tension with a calibration curve. The gypsum also buffers the effect of soil salinity.
Range and accuracy
Useful roughly between −150 and −600 kPa; the block hardly changes in wetter or drier soil. This suits clay soils and crops grown under mild stress (e.g. wine grapes), but in sands and loams much of the water is gone before it responds.
Limits
The gypsum dissolves, so the calibration drifts and blocks last about five years in neutral or alkaline soils but may need yearly replacement in acid soils (not recommended below pH 5). Blocks vary a lot from one to another and need individual calibration.
Soil water tension over a very wide range, from wet to very dry soil, without water to refill. Used mostly in research and in dry environments where tensiometers fail.
How it works
A small heater and a temperature sensor are embedded in a porous ceramic body that comes into balance with the soil's matric potential. A short heat pulse is applied and the temperature rise is measured: water conducts heat well, so a wet ceramic warms less than a dry one.
Range and accuracy
From about −10 kPa to very dry soil (thousands of kPa). Even with a normalized calibration across sensors, a mean absolute error of about 23% was reported over −10 kPa to −35 MPa.
Limits
Each sensor usually needs its own calibration, and readings are sensitive to soil temperature changes. It uses more power and responds more slowly than other matric potential sensors.
Soil water tension over a wide range, from wet soil into soil far drier than a tensiometer can read. Low-maintenance and low-power, so it suits long-term logging.
How it works
One or two porous ceramic discs are buried in the soil and exchange water with it until they reach the same water potential. A small dielectric (capacitance) sensor measures the water content of the ceramic, and the ceramic's own known water retention curve converts that to water potential, so the reading does not depend on the soil type.
Range and accuracy
Matric potential in kPa, from near saturation to about −1000 kPa (−1 MPa) or drier depending on the ceramic, compared with about −85 kPa for a water-filled tensiometer.
Limits
Accuracy depends on how well the ceramic's retention curve is calibrated, and ceramics can differ. The discs need close contact with the soil and take time to equilibrate, especially in dry soil.
The electrical conductivity of water squeezed out of a soil sample brought to saturation. It is the reference measure of soil salinity, because crop salt tolerance tables and the saline-soil classes are written in ECe.
How it works
In the lab, distilled water is stirred into dried soil until it reaches a defined “saturated paste” end point; the liquid is then pulled out with a suction filter. Dissolved salts carry electric current, so the extract's conductivity rises with its salt content. Because finer soils hold more water at saturation, the extract automatically scales with soil texture.
Range and accuracy
Decisiemens per meter (dS/m) at 25 °C. In the US classification, soils above 4 dS/m are saline; below 2 dS/m is preferred. The salt concentration in the extract is roughly half that of the soil solution at field capacity. Quicker 1:1 or 1:5 soil-to-water extracts give different numbers and need soil-specific conversion.
Limits
Slow and labor-intensive, and the paste end point depends on operator skill. It is a one-off value for one sample, so many samples are needed to map salinity across a field.
An electronic probe buried in the soil that estimates the salinity of the soil water around the roots, logging it over time. Useful for following salt build-up under irrigation or fertigation.
How it works
The probe measures two things in the bulk soil at once: its electrical conductivity and its permittivity (dielectric constant, which tracks water content). A model then calculates the conductivity of the pore water itself from the two values.
Range and accuracy
dS/m or S/m. The original method was validated for volumetric water contents from 0.10 m³/m³ to saturation and for pore-water conductivity up to 0.3 S/m (3 dS/m).
Limits
The estimate fails in dry soil (below about 0.10 m³/m³ water) and needs good contact with undisturbed soil. It is a model-based estimate, so it should be checked against extracted soil water.
Apparent electrical conductivity (ECa) of the soil, mapped while driving. Because it follows clay content, moisture and salinity, the map shows where the soil changes across a field.
How it works
Rolling coulters act as electrodes: one pair injects a current into the soil and another pair measures the voltage drop. The ratio gives conductivity; spacing the electrodes further apart reads deeper.
Range and accuracy
Millisiemens per meter (mS/m). Typical carts read a shallow layer (about 0–30 cm) and a deep one (about 0–90 to 100 cm). Values are mainly useful relative to each other within a field.
Limits
Moisture and temperature on the day change the readings, so maps from different dates are hard to compare. Needs ground contact, and soil samples are needed to interpret what the zones mean.
Apparent electrical conductivity of the soil, like the contact cart, but without touching the ground — useful on stony, dry or growing fields.
How it works
A transmitter coil creates an alternating magnetic field that induces small currents in the soil. A receiver coil measures the secondary field these currents create, which under normal, low-conductivity conditions is approximately proportional to soil conductivity.
Range and accuracy
mS/m. The common 1 m instrument reads to about 1.5 m depth in vertical-dipole mode and about 0.75 m in horizontal-dipole mode.
Limits
Metal nearby (vehicles, fences, pipes) disturbs the signal. The instrument can drift and needs regular calibration checks; like all EC maps, it needs soil samples to interpret.
The acidity or alkalinity of a soil sample, measured in a lab suspension. It is the basic soil test: pH controls nutrient availability and is used to decide on liming.
How it works
Dried soil is shaken with water or with a dilute 0.01 M calcium chloride (CaCl₂) solution at a fixed ratio, commonly between 1:1 and 1:5. A glass electrode and a reference electrode develop a voltage that depends on hydrogen-ion activity; the meter converts it to pH.
Range and accuracy
pH units. In CaCl₂ the reading is on average about 0.6 units lower than in water. A multi-laboratory study found reproducibility of roughly 2–11 % relative standard deviation.
Limits
Results depend on the method: water or CaCl₂, the soil-to-solution ratio and the salt content of the sample, so values from different labs are not always comparable. Water pH shifts with seasonal salt levels; the CaCl₂ method is more stable.
A portable pH meter whose robust pointed electrode is pushed straight into moist soil or a soil slurry. It gives an on-the-spot pH reading and shows small-scale variation that a mixed lab sample hides.
How it works
Same principle as the lab method: an ion-selective electrode develops a voltage against a reference electrode that depends on hydrogen-ion activity. Field electrodes use tougher materials (for example antimony or epoxy bodies) than the fragile lab glass bulb.
Range and accuracy
pH units. In a study pressing electrodes into soil for 30 seconds, readings were reliable above about 11 % soil moisture and approached the standard CaCl₂ lab value as the soil got wetter.
Limits
Soil moisture changes the reading by up to about 1.5 pH units, more so in clayey soils. In-situ and lab values can differ by more than one unit, so readings need calibration against lab results.
Soil pH mapped across the field while driving, so lime can be applied only where the soil is acidic instead of at one rate everywhere.
How it works
A sampling shank scoops soil and presses it against two ion-selective (pH) electrodes. The electrodes measure the voltage that depends on hydrogen-ion activity, then are rinsed with water before the next sample.
Range and accuracy
pH units across the normal agricultural range, sampled to about 10 cm. One reading every several seconds; less accurate than a lab test and needs a field-specific calibration, but far denser.
Limits
Electrodes wear, need rinse water and regular calibration, and samplers can clog with residue. Only the topsoil is sampled.
A small silicon chip that senses pH and can be buried in the soil to log pH over months. Research aims to follow pH and nitrogen changes in place, without taking samples.
How it works
An ion-sensitive field-effect transistor (ISFET) is a transistor whose gate is an ion-sensitive layer in contact with the soil water instead of a metal contact. Hydrogen ions at that surface change its electrical potential, which shifts the current through the transistor.
Range and accuracy
pH units. In a field test, a buried pH-ISFET recorded soil pH for six months, in good agreement with standard sampling and without losing sensitivity; the same chip design was adapted to nitrate and ammonium.
Limits
Still at research stage. Like any pH electrode it needs a stable reference electrode and good contact with moist soil, and long-term drift in the field is not yet well documented.
A cheap home or field kit that shows soil pH as a color. Good enough to sort soils into acid, neutral or alkaline, but too coarse for lime rates.
How it works
Soil is mixed with an extracting solution containing indicator dyes, which change color with hydrogen-ion concentration. After a set time, the color is compared with a printed chart.
Range and accuracy
pH in steps of 0.5 or 1 unit; one tested kit covered only pH 4.5–7.5. In a university comparison, two of four kits matched lab pH consistently; kits tended to read lower than the lab.
Limits
Accuracy varies widely between brands, and colors are hard to judge in poor light or in dark or turbid extracts. Results outside the kit's range are simply wrong.
Gravimetric, chemical analysisReliability: HighLabDirectSpot reading€Reference method
The reference way to measure plant-available nutrients. A chemical extractant pulls the “available” pool out of a soil sample, and an instrument reads the extract. The extractant decides which nutrient is measured: KCl for nitrate and ammonium; Olsen bicarbonate for phosphorus (the standard for neutral and calcareous soils, as in much of Türkiye); ammonium acetate for K, Ca, Mg and Na; Mehlich-3 read by ICP-OES for P, K, Ca, Mg, Na and micronutrients at once. Total nitrogen is measured separately, by dry combustion or Kjeldahl digestion.
MeasuresNO₃⁻NH₄⁺total NPKCaMgNaSmicronutrients
How it works
Extract, then read: colorimetry (e.g. molybdenum blue for phosphate) or a flow analyzer for nitrate and ammonium, ICP-OES or flame photometry for cations. One Mehlich-3 extract read by ICP gives many elements together, but ICP reads all phosphorus forms, so Mehlich-3 ICP values run higher than colorimetric ones and must be interpreted as a separate test.
Range and accuracy
mg/kg (ppm) of the extracted nutrient. Results are only comparable within one extraction method: an Olsen P value and a Mehlich-3 P value of the same soil are different numbers.
Limits
Slow (days) and one sample stands for a whole area, so dense mapping is costly. On calcareous soils, Bray-1 underestimates phosphorus and Mehlich-3 can disagree with Olsen, so the extractant must match the soil.
Field and farm-lab kits that turn a soil extract into a color and read it by eye, with a pocket reflectometer or with a photometer. One instrument covers many nutrients — only the reagent changes.
MeasuresNO₃⁻NH₄⁺PKSmicronutrients
How it works
Each ion has its own color reaction: nitrate is reduced to nitrite and forms an azo dye; ammonium gives indophenol blue; phosphate gives molybdenum blue; potassium is read as turbidity with tetraphenylborate. The intensity of color (or cloudiness) is proportional to concentration.
Range and accuracy
mg/L in the extract, converted to mg/kg soil. With a reflectometer and a standard extract, nitrate can come within about 5% of the laboratory method; color charts read by eye are semi-quantitative.
Limits
The extract and the kit's calibration define what “available” means, so results are not always comparable with lab tests. Turbidimetric potassium is imprecise, and cadmium-reduction nitrate reagents are toxic.
One measurement principle for many ions: the same meter reads nitrate, potassium, sodium, calcium or pH depending on which electrode is fitted. Used on soil extracts and soil solution, handheld or in the lab, and in research systems that map pH, K and nitrate together while driving.
MeasuresNO₃⁻KNaCapHP
How it works
Potentiometry: a membrane that lets mainly one ion through develops a voltage against a reference electrode, changing by about 59/z mV for every tenfold change in ion activity (Nernst equation). Only the membrane changes from ion to ion. ISFETs put the same membranes on a transistor gate — smaller and faster.
Range and accuracy
Validated and sold for pH, NO₃⁻, K⁺, Na⁺ and Ca²⁺. Phosphate electrodes (cobalt-based) responded to H₂PO₄⁻ from 10⁻⁵ to 10⁻¹ M in research but are not field-ready. On the go, integrated pH–K–nitrate mapping worked best for pH, then K, then nitrate.
Limits
Other ions interfere (chloride and bicarbonate for nitrate electrodes), readings depend on the soil:water ratio, and each electrode drifts and needs its own calibration. The response becomes non-Nernstian at very low concentrations.
Separates the ions in a soil extract and measures each one in a single run — the only portable approach so far that covers nitrate, ammonium, phosphate and potassium together.
MeasuresNO₃⁻NH₄⁺PKCaMg
How it works
In a thin capillary or a microchip channel, an electric field makes each ion travel at its own speed. As they arrive one after another, a contactless conductivity detector (C4D) records a peak for each ion; lab ion chromatography separates ions with a column instead.
Range and accuracy
Prototypes measured NO₃⁻, NH₄⁺, H₂PO₄⁻ and K⁺ in one 5-minute run (repeatability 1–7.5 %), and a microchip system six ions in about 3 minutes, checked against a flow analyzer and ICP.
Limits
Still research prototypes outside the lab. Needs an extraction step, clean filtered samples and careful buffer chemistry.
Nitrate concentration in soil water, measured optically without chemicals. Combined with pore-water samplers, it can follow nitrate in the root zone continuously, for example after each fertigation.
MeasuresNO₃⁻
How it works
Nitrate absorbs ultraviolet light strongly at short wavelengths, about 217–240 nm. Light is passed through a small flow cell filled with soil water and the absorbance gives nitrate concentration; a second wavelength or a model corrects for dissolved organic matter, which also absorbs UV.
Range and accuracy
Milligrams of nitrate per liter of soil solution. A research system combining optical flow cells with pore-water samplers was tested at four field sites over two years.
Limits
Dissolved organic carbon and ferrous iron absorb in the same UV region and must be corrected for. The sensor needs a supply of soil water from a sampler, so it is mostly used in research and in water monitoring rather than routine farming.
Not a sensor itself, but a tube that draws soil water from a chosen depth so its nitrate, EC or other ions can be measured. Installed below the roots, it shows how much nitrate is leaving the root zone.
How it works
A porous ceramic cup on the end of a PVC tube is placed in the soil. A vacuum of about −0.5 atm inside the tube makes soil water flow through the ceramic into the tube, from where it is pumped out and analyzed.
Range and accuracy
Gives water samples, not a reading; the analysis sets the units (for example mg/L nitrate-N, dS/m). Cheap, installed with an auger without digging a trench, and sampled repeatedly at the same spot.
Limits
It gives a concentration, not the flow of water, so it cannot by itself say how much nitrate is leached. Good contact (a soil slurry around the cup) and a seal along the tube are needed to stop water running down the pipe.
Total concentrations of many elements in soil — such as calcium, iron, potassium and heavy metals — quickly, in the field or the lab. It measures how much of an element is present, not how much is available to plants.
MeasuresKCamicronutrientsP
How it works
A low-power X-ray beam knocks electrons out of the inner shells of atoms. As other electrons fall into the gaps, each element emits X-rays at its own characteristic energy; the energies identify the elements and their intensities give the concentrations.
Range and accuracy
mg/kg to percent, total element content. Results are generally comparable to lab methods for many elements, but in one large comparison phosphorus and magnesium were overestimated by up to 13 and 5 times, so light elements need local recalibration.
Limits
Gives total, not plant-available, nutrients, so it does not replace fertility tests; it is better used as a proxy through calibration. Moisture lowers the signal: dried samples are best, and very wet samples (above about 30 % moisture) give poor accuracy for some elements.
Total elemental content of soil in seconds, with handheld or vehicle-mounted instruments. An emerging way to map potassium and other cations at high density.
MeasuresKPCaMgmicronutrients
How it works
A short laser pulse turns a tiny spot of soil into a hot plasma. As the plasma cools, each element emits light at its own wavelengths; a spectrometer reads these emission lines and a calibration converts them to contents.
Range and accuracy
Total contents (not plant-available fractions). In a field study, K, Ca, Mg, P, Fe, Mn and Cu were predicted well, potassium and iron very well.
Limits
Matrix effects (moisture, texture, particle size), unstable signals and high detection limits for some elements. Measures totals, so plant-available nutrients need a regression model.
Resistive, conductometricReliability: Not reliableIn situHandheldProxy, needs calibrationContinuous€Commercial
Not a nutrient measurement. Cheap stainless-pin probes sold as measuring nitrogen, phosphorus and potassium actually measure electrical conductivity (and often moisture and temperature); the N, P and K numbers are calculated from EC. Do not use them for fertilizer decisions.
How it works
The pins measure soil conductivity, like any EC sensor. A generic factory equation then converts that single electrical signal into three “nutrient” values — so N, P and K always rise and fall together with EC.
Range and accuracy
In a field study the N, P and K outputs correlated with EC at r > 0.91, so they added no information. In a controlled test two such probes were almost insensitive to nitrate, while a true ion-selective probe responded.
Limits
Useful at most as a cheap EC and moisture logger. Evidence on what they measure is strong and consistent; evidence on their agronomic value is thin, and no extension service has endorsed them.
Small plastic probes with a resin membrane, buried in the soil for a set period. They capture nutrient ions as roots would, giving the soil's nutrient supply rate over the burial period rather than a one-moment stock.
MeasuresNO₃⁻NH₄⁺PKCaMgSmicronutrients
How it works
Synthetic ion-exchange resins hold charged sites: cation membranes capture ions such as potassium and ammonium, anion membranes capture nitrate and phosphate as they diffuse from the soil. After removal, the ions are washed off in the lab and measured.
Range and accuracy
Amount of each ion captured per membrane area over the burial time. Several nutrients are measured from one probe; commercial versions are used in soil fertility assessment and fertilizer recommendations.
Limits
Results depend on soil moisture, temperature and contact during burial, and are not directly comparable with standard soil-test numbers. Probes must be retrieved and sent to a lab, so there is no live reading.
Gravimetric, chemical analysisReliability: HighLabDirectSpot reading€€€Reference method
The total carbon content of a soil sample. It is the reference method for soil organic carbon, which drives soil fertility and structure and is the number tracked in carbon-storage monitoring.
How it works
A few milligrams of finely ground soil are burned in pure oxygen at about 900–1000 °C (or 1400–1600 °C in some instruments). All carbon turns into carbon oxides, mainly CO₂, which a gas detector measures.
Range and accuracy
Percent carbon (or g/kg) by mass. The instrument is calibrated with certified reference materials; precision is checked with replicate analyses.
Limits
It measures organic and inorganic carbon together. In calcareous soils, carbonates must be removed with acid first or measured separately and subtracted. Instruments are costly and the tiny sample must be well homogenized.
Gravimetric, chemical analysisReliability: MediumLabProxy, needs calibrationSpot reading€Reference method
The easily oxidized organic carbon in a soil sample, often converted to an organic-matter percentage. It is the classic, low-cost organic matter test of soil fertility labs.
How it works
The soil is mixed with potassium dichromate and concentrated sulfuric acid; the heat of the reaction oxidizes the organic carbon. The dichromate left over is back-titrated with ferrous sulfate, or the Cr³⁺ formed is read by colorimetry at 588 nm.
Range and accuracy
Percent organic carbon or organic matter. Recovery is incomplete — typically 75–90 % in surface soils, about 77 % on average in the original work — so a correction factor of 1.3 is applied. In Türkiye, official organic-matter interpretation tables are based on Walkley-Black results.
Limits
Recovery varies with soil type and depth, so the fixed 1.3 factor adds error. Chloride and ferrous iron give high results, manganese oxides low ones, and charcoal-rich soils are unsuitable. Dichromate is carcinogenic and leaves chromium waste that needs special disposal.
Gravimetric, chemical analysisReliability: LowLabProxy, needs calibrationSpot reading€Reference method
An estimate of soil organic matter from the weight a dried sample loses when it is burned. It is a simple, cheap test that needs no hazardous reagents.
How it works
The sample is oven-dried at 105 °C and weighed, then heated in a muffle furnace at about 550 °C until its weight is constant. The weight lost is taken as burned organic matter; organic carbon is often estimated as about half of it.
Range and accuracy
Percent organic matter by mass. Reliable when organic matter is high (10 % or more); below about 4–6 % the loss is small and comparable to errors and to mass lost by minerals.
Limits
Clays lose structural water and carbonates can decompose when heated, so LOI overestimates organic matter in clayey, calcareous and low-organic soils such as subsoils. It needs a calibration against a reference method for each soil type.
Fast estimates of organic carbon and several other properties (clay, carbonate, total nitrogen, water) from one light spectrum of a dried, ground sample. It lets labs analyze many thousands of samples at low cost per sample.
Measurestotal NPK
How it works
A spectrometer records how the soil reflects visible and near-infrared light (about 350–2500 nm) or mid-infrared light. Organic and mineral bonds absorb at specific wavelengths, and statistical models calibrated on samples analyzed by a reference method turn the spectrum into soil properties.
Range and accuracy
Percent organic carbon and other properties, estimated. One scan takes a few seconds and uses no chemicals; accuracy depends on the calibration and on how well the sample fits the spectral library (a shared collection of spectra with reference analyses).
Limits
It is an indirect, data-driven method: models can overfit, and samples unlike those in the library should not be predicted. Laboratory instruments cost tens of thousands of US dollars, and results from different labs or instruments must be harmonized.
Estimates of soil organic matter and moisture, and sometimes clay, measured in the furrow while driving or planting.
How it works
A window on a shank or seed-firmer slides through the soil. A light source and detector record how the soil reflects visible and near-infrared light, and calibration models turn the spectrum into soil properties.
Range and accuracy
Organic matter in percent and moisture estimates; accuracy depends on how well the calibration fits the local soils.
Limits
Needs local calibration; moisture and residue change the spectrum. The window wears and must stay clean.
Soil temperature at a set depth. It decides when seeds can germinate (maize, for example, is usually sown once the soil is around 10 °C) and feeds crop and pest models.
How it works
The sensing element changes its electrical resistance with temperature. A platinum resistance thermometer (RTD, usually a Pt100 with 100 Ω at 0 °C) changes almost linearly; a thermistor, a semiconductor, changes much more strongly but non-linearly.
Range and accuracy
Degrees Celsius; typically about ±0.1–0.5 °C depending on the sensor (a standard class B Pt100 is within about ±0.4 °C at 20 °C). Standard meteorological depths are 5, 10, 20, 50 and 100 cm.
Limits
The value depends strongly on depth, soil cover and moisture, so probes must sit at a known depth. A Pt100 needs four-wire wiring to cancel cable resistance; tiny thermistors can self-heat. Exposed cables or housings heated by the sun bias shallow readings.
Temperature at the tip of a thin pair of wires. In soil it is used where many small, fast-responding sensors are needed, for example in research profiles.
How it works
Two wires of different metals are joined at the measuring end. A temperature difference along the wires creates a small voltage (Seebeck effect) — about 40 µV per °C for the common Type K — that depends on the difference between the junction and the open ends.
Range and accuracy
Degrees Celsius. The signal is only microvolts, so a sensitive voltmeter and cold-junction compensation (measuring the temperature of the logger terminals with a thermistor or Pt100) are needed.
Limits
Less accurate than resistance thermometers: errors arise along the whole wire and extension cable and from the cold-junction measurement, and field calibration is impractical. For this reason it is not recommended for standard meteorological stations.
Temperature along the whole length of a buried optical fiber, giving thousands of readings at once. In soil science it is used to follow heat flow and, indirectly, changes in soil moisture over large areas.
How it works
Laser pulses are sent into the fiber. A small part of the light is scattered back (Raman scattering) at a higher (anti-Stokes) and a lower (Stokes) frequency; the anti-Stokes part depends on temperature, so their ratio gives temperature, and the return time of the light gives the position.
Range and accuracy
Degrees Celsius along cables up to about 30 km, with about 1 m spatial resolution and down to 0.01 °C temperature resolution; precision trades off against measuring time and spatial resolution.
Limits
The interrogator is expensive and needs careful calibration, so DTS stays a research tool. Deriving soil moisture from temperature is uncertain and depends on knowing the exact cable depth.
Soil resistance to penetration with depth. It shows whether, and at what depth, a compacted layer blocks roots — the basis for deciding where to subsoil.
How it works
A cone on a rod is pushed steadily into the soil by hand. The force divided by the cone's base area gives the cone index; electronic models log it against depth.
Range and accuracy
Megapascals (MPa) or psi. Root growth already slows at lower values and is commonly considered strongly restricted above about 2 MPa (about 300 psi).
Limits
Readings depend heavily on soil moisture — dry soil always reads hard — so measure near field capacity. Stones can give false peaks, and keeping a steady push by hand is hard.
Cone index profiles taken quickly at many geo-referenced points from a vehicle, to map where and how deep compaction occurs across a field.
How it works
The vehicle stops at each point and a hydraulic cylinder, often run from the tractor’s hydraulics, drives one or several standard cones into the soil at a constant speed. A load cell and a depth sensor log the cone index against depth, and a GNSS receiver records the position.
Range and accuracy
Megapascals of cone index versus depth. The standard insertion speed is 30 mm/s; holding speed and angle constant gives less erratic profiles than hand pushing.
Limits
Still a point measurement: the machine must stop at every location, so maps remain fairly coarse. Results still depend on soil moisture, and non-standard cone shapes or speeds are not directly comparable with standard data.
A continuous map of the soil’s mechanical resistance at one or several depths, measured while a tine or blade is pulled through the field. It can guide variable-depth tillage, such as subsoiling only where needed.
How it works
Load cells or strain gauges on a tine, or on narrow blades set at different depths (for example 0–10, 10–20 and 20–30 cm), measure the horizontal force needed to cut the soil. A GNSS receiver tags each reading with its position.
Range and accuracy
Cutting force in newtons or a resistance per unit area, related to cone index by calibration. In one prototype test at 5.7 km/h, the fit with cone index was only moderate (r² about 0.45–0.58).
Limits
Draft force also changes with speed, depth, soil moisture and texture, and friction on the tool must be separated from cutting force. Most systems are still prototypes tested in few fields.
Gravimetric, chemical analysisReliability: HighLabDirectSpot reading€Reference method
Soil bulk density: the dry mass of soil per unit volume. It is the direct reference for compaction and also converts gravimetric water content (g of water per g of soil) into volumetric water content.
How it works
A thin-walled steel cylinder of known volume (usually 100–250 cm³) is driven into the soil and dug out with an undisturbed sample that fills it exactly. The soil is oven-dried at 105 °C; dry mass divided by cylinder volume gives bulk density.
Range and accuracy
Grams per cubic centimeter (g/cm³); typical soils range from about 1.0 to 1.7 g/cm³. Values that restrict roots depend on texture, for example above about 1.80 g/cm³ in sands and about 1.47 g/cm³ in clays.
Limits
Slow, destructive spot sampling. Hard, stony, very wet or loose soils and dense roots make an undisturbed core difficult, and hammering the cylinder can itself compress the sample.
Whether leaves are wet, and for how long. Many fungal diseases need hours of leaf wetness to infect, so disease forecasting models and spray timing rely on it.
How it works
A flat, often leaf-shaped plate carries interlocking electrodes. A film of dew or rain on the surface changes the electrical resistance or capacitance between them.
Range and accuracy
Wet or dry (or a wetness level), reported as wetness duration in hours.
Limits
An artificial plate does not wet and dry exactly like a real leaf; resistance grids are often painted so small dew droplets are detected. Height, angle and orientation change the result — a common setup is 30 cm high, tilted 30–45°, facing north.
Air temperature and relative humidity: the inputs for frost warnings, disease models, vapor pressure deficit (VPD) and evapotranspiration.
How it works
Temperature comes from a thermistor or platinum resistance element; humidity from a thin polymer film whose capacitance changes as it absorbs water vapor. Both sit inside a ventilated radiation shield so the sun does not heat them.
Range and accuracy
About −40 to +60 °C (±0.2–0.5 °C) and 0–100% relative humidity (about ±2–3%, worse above about 90%). Usually measured at about 1.5–2 m.
Limits
Without a proper shield, readings can be a few degrees too high on sunny, calm days. Humidity sensors drift and become less accurate near saturation.
Rainfall amount and intensity. Feeds the soil water balance, irrigation decisions and disease models.
How it works
In the common tipping-bucket gauge, a funnel fills a small see-saw bucket; each time it holds a fixed amount it tips, empties and closes a switch, and the pulses are counted.
Range and accuracy
Millimeters of rain, usually about 0.2–0.25 mm per tip (some models 0.1 mm).
Limits
Under-reads in heavy rain (above about 50 mm/h) and strong wind. Leaves, insects and dirt block the funnel, the gauge must stay level, and snow needs a heated gauge.
Wind speed and direction. Decides whether spraying is safe from drift, and feeds evapotranspiration calculations.
How it works
Spinning cups turn at a speed proportional to the wind and produce pulses; a vane points into the wind and a potentiometer or magnetic sensor reads its angle. Ultrasonic models time sound pulses between transducers and have no moving parts.
Range and accuracy
Meters per second, typically within a few tenths of a m/s, and degrees. Measured at 2 m for evapotranspiration and 10 m for standard weather observations.
Limits
Bearings wear and cups can ice up. Trees and buildings nearby distort the flow; keep the sensor at least about ten times the obstacle's height away from it.
Total incoming solar radiation. The energy term in evapotranspiration formulas such as FAO Penman–Monteith, and an input for crop growth models.
How it works
A thermopile under a glass dome heats up in proportion to the sunlight it absorbs and produces a small voltage; cheaper models use a silicon photodiode.
Range and accuracy
Watts per square meter; roughly 1000 W/m² at midday under clear summer skies (less in winter, more at altitude).
Limits
The dome must be clean, dry and level. Photodiode models respond unevenly across the spectrum, so they are less accurate under clouds or canopy.
Several weather sensors on one mast, plus a datalogger that turns them into farm numbers: reference evapotranspiration (ET₀), growing degree days, frost alerts and disease risk.
How it works
A datalogger samples each sensor, averages the readings, computes derived values and sends them by mobile network or low-power radio to a web platform.
Range and accuracy
Typically temperature, humidity, rain, wind, solar radiation, often leaf wetness and soil sensors; readings every few minutes.
Limits
One station represents only its surroundings, so hilly or varied land needs more. Needs a good site, power and regular cleaning and calibration.