Laboratory soil pH (glass electrode)FR pH du sol au laboratoire (électrode de verre) (pH eau, pH CaCl₂)TR Laboratuvarda toprak pH'ı (cam elektrot) (Toprak pH analizi, su ile pH, CaCl₂ ile pH)
Also called: Soil pH test, pH in water, pH in CaCl₂
PotentiometricReliability: HighLabDirectSpot reading€Reference method
The acidity or alkalinity of a soil sample, measured in a lab suspension. It is the basic soil test: pH controls nutrient availability and is used to decide on liming.
- How it works
- Dried soil is shaken with water or with a dilute 0.01 M calcium chloride (CaCl₂) solution at a fixed ratio, commonly between 1:1 and 1:5. A glass electrode and a reference electrode develop a voltage that depends on hydrogen-ion activity; the meter converts it to pH.
- Range and accuracy
- pH units. In CaCl₂ the reading is on average about 0.6 units lower than in water. A multi-laboratory study found reproducibility of roughly 2–11 % relative standard deviation.
- Limits
- Results depend on the method: water or CaCl₂, the soil-to-solution ratio and the salt content of the sample, so values from different labs are not always comparable. Water pH shifts with seasonal salt levels; the CaCl₂ method is more stable.
Linked fromFertilization › Phosphorus (P), Fertilization › Ammonium sulfate (21-0-0, 24 % S), Fertilization › Soil test interpretation, Fertilization › Soil pH, liming and acidification, Soil › Soil pH and buffering, Soil › Acid soils of the Black Sea coast