Saturated paste extract EC (ECe)FR Conductivité de l'extrait de pâte saturée (CEe) (Test de pâte saturée, test de salinité du sol)TR Saturasyon ekstraktında EC (ECe) (Saturasyon çamuru testi, tuzluluk analizi)
Also called: Saturated paste test, ECe test, soil salinity test
Resistive, conductometricReliability: HighLabDirectSpot reading€Reference method
The electrical conductivity of water squeezed out of a soil sample brought to saturation. It is the reference measure of soil salinity, because crop salt tolerance tables and the saline-soil classes are written in ECe.
- How it works
- In the lab, distilled water is stirred into dried soil until it reaches a defined “saturated paste” end point; the liquid is then pulled out with a suction filter. Dissolved salts carry electric current, so the extract's conductivity rises with its salt content. Because finer soils hold more water at saturation, the extract automatically scales with soil texture.
- Range and accuracy
- Decisiemens per meter (dS/m) at 25 °C. In the US classification, soils above 4 dS/m are saline; below 2 dS/m is preferred. The salt concentration in the extract is roughly half that of the soil solution at field capacity. Quicker 1:1 or 1:5 soil-to-water extracts give different numbers and need soil-specific conversion.
- Limits
- Slow and labor-intensive, and the paste end point depends on operator skill. It is a one-off value for one sample, so many samples are needed to map salinity across a field.
Linked fromSoil › Saline and sodic soils, Soil › Salinization of irrigated land