ThermocoupleFR Thermocouple (Thermocouple de type K, thermocouple de type T)TR Termokupl (K tipi termokupl, T tipi termokupl)

Also called: Type K thermocouple, Type T thermocouple

ThermalReliability: MediumIn situDirectContinuous€Commercial

Temperature at the tip of a thin pair of wires. In soil it is used where many small, fast-responding sensors are needed, for example in research profiles.

How it works
Two wires of different metals are joined at the measuring end. A temperature difference along the wires creates a small voltage (Seebeck effect) — about 40 µV per °C for the common Type K — that depends on the difference between the junction and the open ends.
Range and accuracy
Degrees Celsius. The signal is only microvolts, so a sensitive voltmeter and cold-junction compensation (measuring the temperature of the logger terminals with a thermistor or Pt100) are needed.
Limits
Less accurate than resistance thermometers: errors arise along the whole wire and extension cable and from the cold-junction measurement, and field calibration is impractical. For this reason it is not recommended for standard meteorological stations.

Sources: [69]

50–1000 mm

Sources

  1. Guide to Instruments and Methods of Observation (WMO-No. 8), Vol. I, Chapter 2: Measurement of Temperature. World Meteorological Organization, 2018.