ThermocoupleFR Thermocouple (Thermocouple de type K, thermocouple de type T)TR Termokupl (K tipi termokupl, T tipi termokupl)
Also called: Type K thermocouple, Type T thermocouple
ThermalReliability: MediumIn situDirectContinuous€Commercial
Temperature at the tip of a thin pair of wires. In soil it is used where many small, fast-responding sensors are needed, for example in research profiles.
- How it works
- Two wires of different metals are joined at the measuring end. A temperature difference along the wires creates a small voltage (Seebeck effect) — about 40 µV per °C for the common Type K — that depends on the difference between the junction and the open ends.
- Range and accuracy
- Degrees Celsius. The signal is only microvolts, so a sensitive voltmeter and cold-junction compensation (measuring the temperature of the logger terminals with a thermistor or Pt100) are needed.
- Limits
- Less accurate than resistance thermometers: errors arise along the whole wire and extension cable and from the cold-junction measurement, and field calibration is impractical. For this reason it is not recommended for standard meteorological stations.
Sources: [69]
50–1000 mm